Login for faster access to the best deals. Click here if you don't have an account.
Warning ! This ad has expired. The product or service is not more available (may be)

XANTREX C40 CHARGE CONTROLLER Private Seller

4 years ago Parts & Miscellaneous  Key West, FL 492 Views 0 Watching
Title: XANTREX C40 CHARGE CONTROLLER
Country:US
State or Province:FL
City: Key West
Type of Sale:Private Seller
Listed:4 years ago
Location: Key West, FL
Price : $50

Xantrex C40 PWM Charge Controller

The Xantrex C40 PWM Charge Controller can be used for most DC Charging Sources. The C40 may be configured for either 12, 24 or 48 volt DC systems.

It can be used as a charge, diversion, or load controller and comes with a standard multi color charge status LED. Standard Features include a Silent Microprocessor Control.

3 Stage Battery Charging means the C Series controllers automatically initiate a 3 stage battery charging cycle. Bulk, Absorption, and Float modes are used to ensure that voltage and current settings accurately match the batteries' actual state of charge. This means fast as possible charging and extended battery life.

Bulk and Float voltage set points are programmable which allows us to use a wide variety of battery technologies including; flooded lead acid, gel, and absorbed glass mat AGM . In addition, there are manually selectable settings for Nicad batteries.

When used as a load controller, the C Series will automatically turn a DC load on or off at predetermined battery voltage settings. Both LVD low voltage disconnect and LVR low voltage reconnect set points are user adjustable.

In DC Diversion Mode all power, which is not used to maintain a full charge on the batteries, is diverted to a load dump such as low voltage water or space heaters. Diversion mode is used to regulate micro hydro and wind turbine systems which need a constant load.

A simple to read, multi color LED indicates operating status and is standard on all C Series controllers.

Electrical Specifications: Voltage Configurations: 12/24/48Vdc. Max. PV Open Circuit Array Voltage: 125Vdc. Charging / Load Current: 40 amps DC. Max. Peak current: 85 amps Max. Voltage Drop through Controller: 0.30 volts. Typical Operating Consumption: 15 ma.Typical Idle Consumption: 3 ma. Recommended Breaker Size: 50 amps. Enclosure Type: Indoor, ventilated, powder coated steel with 3/4" and 1" knockouts. Unit Weight: 2.5 Lb"s 1.2 kg . Dimensions H x W x D : 10 x 5 x 2.5" 25.4 x 12.7 x 6.35 cm Mounting: Vertical wall mount indoor only.

I will ship this for 13.00 anywhere in CONUS.

Beware of Scams

Public Discussion about this ad - XANTREX C40 CHARGE CONTROLLER



 

Revision Date: 2019-07-11 20:42:28
By User: Harry043
Revised Field: phone

Old Value New Value
14074055252

Revision Date: 2019-07-11 20:42:28
By User: Harry043
Revised Field: contact_name

Old Value New Value
Harry043

Revision Date: 2019-07-11 20:42:28
By User: Harry043
Revised Field: description

Old Value New Value
<p style="text align:center;"><span style="color:rgb 128,0,0 ;"><span>Xantrex C40 PWM Charge Controller</span></span></p><p>The Xantrex C40 PWM Charge Controller can be used for most DC Charging Sources. The C40 may be configured for either 12, 24 or 48 volt DC systems.</p><p>It can be used as a charge, diversion, or load controller and comes with a standard multi color charge status LED. Standard Features include a Silent Microprocessor Control.</p><p>3 Stage Battery Charging means the C Series controllers automatically initiate a 3 stage battery charging cycle. Bulk, Absorption, and Float modes are used to ensure that voltage and current settings accurately match the batteries' actual state of charge. This means fast as possible charging and extended battery life.</p><p>Bulk and Float voltage set points are programmable which allows us to use a wide variety of battery technologies including; flooded lead acid, gel, and absorbed glass mat AGM . In addition, there are manually selectable settings for Nicad batteries.</p><p>When used as a load controller, the C Series will automatically turn a DC load on or off at predetermined battery voltage settings. Both LVD low voltage disconnect and LVR low voltage reconnect set points are user adjustable.</p><p>In DC Diversion Mode all power, which is not used to maintain a full charge on the batteries, is diverted to a load dump such as low voltage water or space heaters. Diversion mode is used to regulate micro hydro and wind turbine systems which need a constant load.</p><p>A simple to read, multi color LED indicates operating status and is standard on all C Series controllers.</p><p>Electrical Specifications: Voltage Configurations: 12/24/48Vdc. Max. PV Open Circuit Array Voltage: 125Vdc. Charging / Load Current: 40 amps DC. Max. Peak current: 85 amps Max. Voltage Drop through Controller: 0.30 volts. Typical Operating Consumption: 15 ma.Typical Idle Consumption: 3 ma. Recommended Breaker Size: 50 amps. Enclosure Type: Indoor, ventilated, powder coated steel with 3/4" and 1" knockouts. Unit Weight: 2.5 Lb"s 1.2 kg . Dimensions H x W x D : 10 x 5 x 2.5" 25.4 x 12.7 x 6.35 cm Mounting: Vertical wall mount indoor only.</p> <p>Xantrex C40 PWM Charge Controller</p><p>The Xantrex C40 PWM Charge Controller can be used for most DC Charging Sources. The C40 may be configured for either 12, 24 or 48 volt DC systems.</p><p>It can be used as a charge, diversion, or load controller and comes with a standard multi color charge status LED. Standard Features include a Silent Microprocessor Control.</p><p>3 Stage Battery Charging means the C Series controllers automatically initiate a 3 stage battery charging cycle. Bulk, Absorption, and Float modes are used to ensure that voltage and current settings accurately match the batteries' actual state of charge. This means fast as possible charging and extended battery life.</p><p>Bulk and Float voltage set points are programmable which allows us to use a wide variety of battery technologies including; flooded lead acid, gel, and absorbed glass mat AGM . In addition, there are manually selectable settings for Nicad batteries.</p><p>When used as a load controller, the C Series will automatically turn a DC load on or off at predetermined battery voltage settings. Both LVD low voltage disconnect and LVR low voltage reconnect set points are user adjustable.</p><p>In DC Diversion Mode all power, which is not used to maintain a full charge on the batteries, is diverted to a load dump such as low voltage water or space heaters. Diversion mode is used to regulate micro hydro and wind turbine systems which need a constant load.</p><p>A simple to read, multi color LED indicates operating status and is standard on all C Series controllers.</p><p>Electrical Specifications: Voltage Configurations: 12/24/48Vdc. Max. PV Open Circuit Array Voltage: 125Vdc. Charging / Load Current: 40 amps DC. Max. Peak current: 85 amps Max. Voltage Drop through Controller: 0.30 volts. Typical Operating Consumption: 15 ma.Typical Idle Consumption: 3 ma. Recommended Breaker Size: 50 amps. Enclosure Type: Indoor, ventilated, powder coated steel with 3/4" and 1" knockouts. Unit Weight: 2.5 Lb"s 1.2 kg . Dimensions H x W x D : 10 x 5 x 2.5" 25.4 x 12.7 x 6.35 cm Mounting: Vertical wall mount indoor only.</p><p>I will ship this for 13.00 anywhere in CONUS.</p>
Login or register to post to this thread